Dell PowerVault DL4000 Owner's Manual page 87

Dell powervault dl4000 systems owner's manual
Hide thumbs Also See for PowerVault DL4000:
Table of Contents

Advertisement

Error Code
Message Information
Action
CPU0001
Message
Details
Action
CPU0005
Message
Details
Action
CPU0010
Message
Details
Action
CPU0023
Message
Action
CPU0204
Message
Details
Action
CPU0700
Message
Details
Action
Review System Event Log and Operating System Logs. If the issue
persists, see
Getting
Help.
number > has a thermal trip (over-temperature) event.
CPU <
The processor temperature increased beyond the operational range.
Review the logs for fan failures. If no fan failures are detected, check
inlet temperature (if available) and reinstall processor heat sink. If the
problem persists, see
Getting
number > configuration is unsupported.
CPU <
System is unable to boot or may run in a degraded state.
Review the technical specifications for supported processor types.
number > is throttled.
CPU <
The CPU is throttled due to thermal or power conditions.
Review system logs for power or thermal exceptions.
number > is absent.
CPU <
Verify processor installation. If present, re-seat the processor.
number > < name > voltage is outside of range.
CPU <
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
number > initialization error detected.
CPU <
System BIOS was unable to initialize the processor.
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
Help.
Getting
Help.
Getting
Help.
87

Advertisement