No.
Item
19
Paper transport stability (*13)
Notes:
1) This specification applies to the
recommended paper.
2) No options
20
Electrical
Notes:
1) Momentary power failure, AC
line noise, pulse noise,
momentary variation of supply
voltage, antistaic strength,
EMC, lightning surge are tested
by the test printing function
built in the engine.
2) SG and FG are always
connected.
*12
Do not print on the blank side of used media. It may cause stains on paper and/or decrease of printing capability.
*13
Moistened media may lower toner transferring conditions and paper feeding capability.
*14
The rated voltage of input power differs with countries of destination and their regulations. See Item no. 28.
Specification
Paper crease: single-sided; 1/1,000 sheets
double-sided; 1/500 sheets
Conditions and environment
• Printing ratio: 5%
• 23˚C, 50% RH
• Recommended paper
Notes:
1) Paper feeding with the MFF may crease a sheet of paper
depending on loading conditions.
2) Light crease having no practical problem (no affect to legibility)
should not be counted.
Paper curl:
30 mm or less
Conditions and environment
• Printing ratio: 5%
• 23˚C, 50% RH
• Recommended paper
Input voltage
110 to 120 VAC +6%/-10%, 50/60 Hz +2%/-4%
(*14)
220 to 240 VAC +6%/-10%, 50/60 Hz +2%/-4%
Input current
9 A or less (120 VAC)
4.5 A or less (230 VAC)
Power consumption
Maximum
700W (at 120 VAC or 230 VAC, excluding inrush
current)
Average
450 Wh or less (at 120 VAC or 230 VAC)
during printing
Sleep mode
45 Wh or less (at 120 VAC or 230 VAC)
Insulation resistance
(primary-ground)
Dielectric strength, one minute 1,000 VAC (120 VAC)
(primary-ground)
Leakage
0.5 mA or less (at 120 VAC and 60 Hz)
current
3.5 mA or less (at 230 VAC and 60 Hz)
Inrush current
90 A or less (at 120 VAC or 230 VAC and 60 Hz)
(for cold start)
Applied to first turnig on after leaving power
turned off more than 12 minutes.
Momentary
0.5-cycle 100% dip at 120 VAC or 230 VAC (50/
power failure
60 Hz)
AC line noise
1 kV or more, pulse width 100 to 800 ns
Electrostatic strength
(conforming to IEC 801-2/91) 150 , 150 pF
Surge voltage (lightning)
10 M or more with 500 V megger
1,500 VAC (230 VAC)
9 kV or more
(no mismovement, no misprinting)
1.2 kV, pulse width: 40 8 s