Fig. 3
Multifamily house with 6 private apartments
»
System type: audio/video combined
»
Wiring: rising mains with branch connections, i.e. video
distributors
»
Devices used:
» One ABB-Welcome video outdoor station,
6gang, article number: 83122/6-xxx-500
» Four ABB-Welcome audio indoor stations with handset,
article number: 83205 AP-xxx-500
» Two ABB-WelcomeTouch,
article number: 83220 AP-xxx-500
» ABB-Welcome system controller,
article number: 83300-500
» Three ABB-Welcome video distributors, FM indoor,
article number: 83320/2 U-500
» Six floor call buttons
» One electric door opener
The combined audio/video solution for the multifamily house
with six private apartments. The wiring from the ABB-Welcome
system controller to the indoor stations is designed as rising
mains. From here the wires branch off into the apartments. Each
of the two bottom floors has an ABB-Welcome audio indoor sta-
tion with handset installed. All branch connections require video
distributors.
Fig. 4
Commercial object
»
System type: audio/video
»
Wiring: looped from device to device
»
Devices used
» One ABB-Welcome video outdoor station, 1gang,
article number: 83121/1-xxx-500
» One ABB-Welcome audio outdoor station, 1gang,
article number: 83101/1-xxx-500
» One ABB-Welcome audio indoor station with display,
article number: 83200 U, cover plates article number:
83260-xxx-500 2gang frame
» One ABB-WelcomeTouch,
article number: 83220 AP-xxx-500
» One ABB-Welcome system controller,
article number: 83300-500
» One ABB-Welcome video outdoor distributor,
article number: 83325/2-500
» One ABB-Welcome bell transformer,
article number: 83315-500
» One switch actuator, door/light,
article number: 83330-500
» Two electric door openers
The combined audio/video solution for a building with several
entrances – such as private apartment and office. One indoor
station is located on the left at the office entrance, another one
on the right at the apartment. Inside the building the two internal
bus lines of the system controller are used. A distributor is
required to connect the two outdoor stations.