Emectrica{Preparation
ELECTRICAL
PREPARATmON
30 _'
(762mm)
2!
EE
(533mm)
ElectdcaJ Shock Hazard
To avoid electrica!
shock, do not work on an
energized
circuit. Doing so could resuJt in serious
injury or death. OnJy quaJified eJectricians
shouJd
perform etectricaJ work. Do not attempt any work
on the dishwasher
eJectric suppJy circuit until you
are certain the circuit is
de-energized.
Figure 4
Dishwasher
Electrical
Rating
Vemts
Amperes
Watts
120
60
15
1,450
(max)
(76mm-
102mm)
3/8"-
1/2"
_
.<
(10mm - 13mm)
<
J
Figure 5
Fire Hazard
To avoid a fire hazard, make sure eJectdcaJ work
is properJy installed.
OnJy qualified
eJectricians
shouJd perform eJectrical work.
ElectricaJ SuppJy
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shall be a
minimum #14 AWG copper wire rated at 75°C or higher.
Regardless of where the electrical supply cable enters the
enclosure, position the cable 21" (533mm) from the
enclosure's left side, as shown in Figure 4. Extend the
cable 30" (762mm) from the enclosure's back, as shown
in Figure 4,
Remove 3" =4" (76mm =102mm) of the cable's outer
casing, as shown in Figure 5, then remove 3/8" - 1/2"
(10 - 13mm) of insulation from each wire, as shown in
Figure 5,