Sj300 Dynamic Braking Selection Tables - Hitachi SJ300 Series Instruction Manual

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

SJ300
The SJ300 Series 200V and 400V class inverter models in the 1/2 to 15 hp range have internal
braking units. Additional stopping torque is available by adding external resistors. The required
Dynamic Braking
braking torque depends on your particular application. Other tables in this section will help you
Selection Tables
choose the proper resistor.
1/2 to 15 hp (0.4 to 11 kW)
Voltage
Model Number
Class
SJ300–004LFU
SJ300–007LFU
SJ300–015LFU
SJ300–022LFU
200V
SJ300–037LFU
SJ300–055LFU
SJ300–075LFU
SJ300–110LFU
SJ300–007HFU/E
SJ300–015HFU/E
SJ300–022HFU/E
400V
SJ300–040HFU/E
SJ300–055HFU/E
SJ300–075HFU/E
SJ300–110HFU/E
Without
External Resistor
Braking
Motor
Braking
Torque
hp
Unit
@ 60Hz,
%
1/2
Built-in
50
1
Built-in
50
2
Built-in
50
3
Built-in
20
5
Built-in
20
7.5
Built-in
20
10
Built-in
20
15
Built-in
10
1
Built-in
50
2
Built-in
50
3
Built-in
20
5
Built-in
20
7.5
Built-in
20
10
Built-in
20
15
Built-in
10
Using Optional
External Resistor
Minimum Resistance
Braking
External
Minimum
Torque
Resistance,
Resistance,
@60Hz,
Ohms
Ohms
%
50
200
50
200
35
200
35
160
35
100
17
80
17
80
17
70
100
200
100
200
100
200
100
140
70
100
70
100
70
70
SJ300 Inverter
Performance @
Minimum
Resistance
@ 100%
Max.
Braking
Braking
Duty
Duty
Cycle,
Cycle,
Ohms
%
50
10
150
50
10
150
35
10
100
35
10
100
35
10
100
17
10
50
17
10
50
17
10
50
100
10
300
100
10
300
100
10
300
70
10
200
70
10
200
50
10
150
50
10
150
5–7