Icons on the idle display
The following is displayed:
u
the internal number, e.g. INT 1.
u
the quality of the reception signal between base station and handset (signal
strength):
– poor to good: Ò Ñ i Ð
– no reception: | flashes
u
battery charge status:
– = e V U (empty to full)
– = flashes: batteries almost empty
– e V U flashes: charging procedure
No connection to the Internet/VoIP server
If one of the following messages is displayed instead of the internal name after the
connection wizard is closed, errors have occurred:
u
Server not accessible!
u
SIP registration failed
Below you will find possible causes and measures you can take.
Server not accessible!
The phone has no connection to the Internet.
¤
Check the cable connections between the base station and the router (the LED
on the base station must light up) and the connection between the router and
the Internet connection.
¤
Verify that the phone is connected to the LAN.
– It may not have been possible to dynamically assign an IP address to the
phone
or
– You have assigned a static IP address to the phone that has either already
been assigned to another LAN subscriber or does not belong to the router's
address block.
¤
Press the Paging key on the base station. The IP address appears on the hand-
set display.
¤
Press the Talk key on the handset to end paging call.
¤
Start the Web configurator with the IP address.
¤
If no connection can be established, change the settings on the router (acti-
vate DHCP server) or the phone's IP address.