Siemens SITRANS LR 300 Instruction Manual page 80

Iq radar 300
Hide thumbs Also See for SITRANS LR 300:
Table of Contents

Advertisement

P837 Auto False Echo Suppression
Use P837 and P838 during start up, if possible. It works ideally if the tank is empty or at
low levels. Only use this function if there is a minimum 2m distance from the radar unit to
the material. The agitator should be running, if the vessel contains an agitator.
Use this feature to adjust the TVT Curve
height to ignore false echoes on the Echo Profile by placing the TVT above the current
signal. Use P838 to set the Auto TVT length.
Dolphin Plus Display before Auto False Echo Suppression
1.
P837 will be preset to 1 by the factory. This is done to accommodate internal
antenna reflections.
Page 78
(or when P837 = 0)
Default TVT
SITRANS LR 300 – INSTRUCTION MANUAL
1
(F = 1)
P839
Hover Level
7ML19985CL02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents