Inserting & Dropping Data Communications Channel - HP OMNIBER 718 37718A User Manual

Dsn/sonet operation
Table of Contents

Advertisement

Description
HOW TO:
Selecting Test Features
Inserting & Dropping Data Communications Channel
Inserting & Dropping Data
Communications Channel
The Data Communications Channel (DCC) of the regenerator and
multiplexer section overhead can be verified by protocol testing. The
Insert and Drop capability provides access to the DCC via the RS-449
connector on the front panel of the Multirate Analyser module.
DCC INSERT is available on the
display.
DCC DROP is available on the
display.
1 Connect the Protocol Analyzer to the DCC port on the Multirate
Analyzer module.
2 Choose the required DCC.
,
TRANSMIT
SONET
SONET TEST FUNCTION
RECEIVE
,
TEST FUNCTION
65