External Compressed Air Connection; Compressor; Exhaust Ducting (Exhaust Extraction) With Electrically Heated Rollers - Miele MM 50-175 Operating Instructions Manual

Table of Contents

Advertisement

External compressed air
connection
The compressed air connection point is
located at the rear of the right hand side
stand.

Compressor

Ironers with an integrated compressor
If the compressed air container is empty the
ironer's lifting motor will not work. The
pressure reducer on the compressor (see
also instructions for use and maintenance of
the compressor) will therefore need to be
closed (set to 0) when comissioning the
machine, until the pressure container is full.
The manometer on the pressure container
will then show a reading of approx. 8 bar.
The pressure reducer can then be opened
as far as it will go again (to 8).
Exhaust ducting (exhaust
extraction) with electrically heated
rollers
The exhaust ducting stub C100 mm is
located at the rear of the right hand stand.
Make sure that the extraction fan is turning in
the correct direction.
See installation diagram and installation
instructions supplied.
,
After setting up and connecting the
machine ensure that all outer casing parts
are correctly fitted back into position.
M.-Nr. 05 567 240 /03