Switch Settings; Connectors; Installation - NEC Electra Elite IPK II Installation And Maintenance Manual

H.323 trunk
Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

H.323 Trunk
___________________________________________________________________________________
2.2
2.3
2.4
___________________________________________________________________________________
Hardware, Installation and Maintenance Manual

Switch Settings

The IAD(8)-U( ) ETU has two switches that are described below.
Switch S1 is a Press to Reset switch.
Switch S2 is a Card Configuration switch. Refer to
Switch
Settings.
Table 1-2
Switch
S1
Press to Reset
S2
Shown below
S2-1 ~ 3
Always Off
S2-4
On to enable
Off to disable
S2-5
On — enable 8 ports
Off — enable 4 ports
6
ON
S2-6 ~ 8
OFF
ON
OFF
ON

Connectors

This ETU has the following connectors:
P1
Connects to the backboard
J1, J10, J11
Reserved for future use
J5
RJ-45 Ethernet connector for future use
J6
Default RJ-45 Ethernet connector

Installation

The IAD (8)-U( ) ETU can be installed in any KSU slot that supports the
applicable simulated ETU.
IAD(8)-U( ) Switch Settings
Setting
Setting Position
7
8
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
Document Revision 1
Table 1-2 IAD(8)-U( )
Description
Host Reset Switch
8-position DIP Switch
Reserved
Auto Card Discovery
Selection
Number of Voice Port
Selection
Mode Selection
COI
COID
DID
TLI
DTI
1 - 3

Hide quick links:

Advertisement

Table of Contents
loading