3.32 [1-1] Slot—Card Property - PRI type
Programming Manual References
None
Feature Manual References
None
ISDN Extension—T308
Specifies the maximum time that the PBX waits for a reply after receiving the Release message from ISDN.
Default
40 ´ 100 ms
Value Range
0–600 ´ 100 ms
Maintenance Console Location
3.32 [1-1] Slot—Card Property - PRI type
Programming Manual References
None
Feature Manual References
None
ISDN Extension—T309
Specifies the length of time that the PBX tries to disconnect the data link, before disconnecting the call.
Default
120 ´ 100 ms
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.32 [1-1] Slot—Card Property - PRI type
Programming Manual References
None
Feature Manual References
None