5.9.4 Installing IP Phones at a Remote Site with a Built-in Media Relay Gateway
4.
Download the config file to the KX-UT series SIP phone via the Web user interface of the KX-UT series
SIP phone. For details, refer to "When the SIP Phones are in a different LAN (Remote site installation)" in
"5.8.1 Assigning IP Addressing Information".
5.
Connect the KX-UT series SIP phone to the LAN in the remote site.
6.
Register the KX-UT series SIP phone to the KX-NS1000 as a remote extension.
a.
Click Setup ® PBX Configuration ® Configuration ® Slot.
b.
Click Virtual ® V-UTEXT32.
c.
Move the mouse pointer over the V-UTEXT32 card (Virtual UT Extension Card).
A menu will be shown under the mouse pointer.
d.
Click Port Property.
e.
Click the Remote Place tab.
f.
Configure the items shown below.
•
Change the value to Remote (MRG) for Phone Location.
•
Change the value to Enable for Web-MC Ability.
•
Select a protocol (HTTP/HTTPS) for Protocol for Remote SIP-MLT.
Note
Select the same value as you selected for NAT - SIP Proxy Server Port No. in step 5 of
"Programming the KX-NS1000" in this section.
g.
Click OK.
7.
Register the KX-UT series SIP phone. For details, refer to "5.9.1 Registering IP Telephones".
Note
•
You can select HTTPS for Protocol for Remote SIP-MLT only when Phone Location is set as
Remote (MRG).
•
If the KX-UT series SIP phone does not work normally, confirm whether the KX-UT series SIP
phone can access the internet.
276