Power Failure Restart; Power Failure Transfer - Panasonic KX-NCP500 Manual Manual

Pure ip-pbx
Hide thumbs Also See for KX-NCP500:
Table of Contents

Advertisement

Conditions
This PBX performs PING as follows:
Test packet length: 56 bytes
Ping attempts: 5
Time out length: 1 second
Ping interval time: 1 second
PC Programming Manual References
2.6.18 Utility—Ping

13.1.10 Power Failure Restart

Description
When the electricity is turned back on, the PBX restarts, loads its stored data automatically, and logs the event
as a System Restart in the error log.
Conditions
In the event of a power failure, PBX memory is protected by a factory-installed lithium battery. There is no
memory loss except the memories of Automatic Callback Busy (Camp-on) (® 1.1.4 Automatic Callback
Busy (Camp-on)) and Call Park (® 3.1.7 Call Park).

13.1.11 Power Failure Transfer

Description
If the power supply to the PBX fails, specific single line telephones (SLTs) are automatically connected to
specific CO lines (Power Failure Connections). The PBX will switch from the current connections to the Power
Failure Connections, and all existing conversations will be disconnected.
Only CO line conversations handled by Power Failure Connections can be made during a power failure.
Conditions
Only CO line calls can be made during a power failure. All other features do not work.
The analog CO line cards, extension cards, and the number of PFT ports (ports which can be used for
Power Failure Connections) are as follows:
CO Line Card: LCOT4 (1 PFT ports)
Extension Card: DHLC4 (1 PFT ports)
Note
Through system programming, it is possible to allow CO line calls that are established during a power
failure to be maintained even when the power returns and the connection is switched back to the normal
configuration from the Power Failure Connection. However, if no special programming is performed,
the connection will be dropped when power returns.
Document Version 2009-12
13.1.11 Power Failure Transfer
Feature Manual
213

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncp1000Ncp500Kx-ncp1000