Panasonic KT2 Instruction Manual page 28

Hide thumbs Also See for KT2:
Table of Contents

Advertisement

[Input abnormality indication]
Output status
Contents and
selection
Indication
when input
abnormal
Overscale
Measured value
has exceeded
Indication range
high limit value.
"
" flashes.
Underscale
Measured value
has dropped
below Indication
range low limit
value.
"
" flashes.
[Output status selection when input abnormal] is available only for DC input and DC current output.
For other inputs and outputs except for DC input and DC current output, the output status will be
the same as when OFF is selected during [Output status selection when input abnormal].
(*): Outputs a value between OFF (4mA) and ON (20mA) or between OUT1 (Heating side) low limit
value and OUT1 (Heating side) high limit value, depending on deviation.
Thermocouple and RTD input
Input
K,T
Pt100
JPt100
Indication range and Control range for thermocouple inputs other than the above:
Input range low limit value –50
DC input
Indication range: Scaling low limit value–Scaling span x 1% to Scaling high limit value– Scaling span x 10%
Control range: Scaling low limit value–Scaling span x 1% to Scaling high limit value– Scaling span x 10%
DC input disconnection: When DC input is disconnected, PV/SV display flashes "
DC and 1 to 5V DC inputs, and "
10V DC inputs, the PV/SV display indicates the value corresponding with 0mA or 0V input.
Circuit insulation configuration
7
Insulation resistance : 10M
Dielectric strength
Supply voltage
Allowable voltage fluctuation: 100 to 240V AC: 85 to 264V AC, 24V AC/DC: 20 to 28V AC/DC
Power consumption
Ambient temperature : 0 to 50
Ambient humidity
Weight
OUT1
Direct
ON (20mA)
or OUT1 high
limit value (*)
OFF (4mA)
or OUT1 low
limit value
OFF (4mA)
or
OUT1 low
limit value
Input range
–199.9 to 400.0
–199.9 to 750.0
–199.9 to 850.0
–200 to 850
–199.9 to 999.9
–300 to 1500
–199.9 to 500.0
–200 to 500
–199.9 to 900.0
–300 to 900
(100 ) to Input range high limit value +50
However,
"
" or "
B
Communication
DI (Digital input)
9
8
EV1/OUT2 output
CPU
Insulated
Input
Power
OUT1
A
1
2
3
4
5
or more, at 500V DC
: 1.5kV AC for 1 minute between input terminal and power terminal
1.5kV AC for 1 minute between output terminal and power terminal
: 100 to 240V AC 50/60Hz, 24V AC/DC 50/60Hz
: Approx. 5VA
(32 to 122 )
: 35 to 85%RH (no condensation)
: Approx. 120g
Output status
Controller
Reverse
Direct
OFF(4mA)
or
OFF
OUT1 low
limit value
ON
(20mA)
or
ON
OUT1 high
limit value (*)
OFF(4mA) or
OUT1 low
OFF
limit value
Indication range
–199.9 to 450.0
–199.9 to 850.0
–199.9 to 900.0
–210 to 900
–199.9 to 999.9
–318 to 1600
–199.9 to 550.0
–207 to 550
–199.9 to 999.9
–312 to 1000
" flashes when the range of –1999 to 9999 is exceeded.
" for 0 to 1V DC input. For 0 to 20mA DC, 0 to 5V DC and 0 to
11
12
10
10
12
When OUT1 is non-contact voltage output or
DC current output, A is not insulated from B.
12
11
EV2 output
A: Terminals 3, 4
B: Terminals 10, 11, 12
6
28
Converter
OUT2
Reverse
Direct
ON (20mA)
ON
or
OUT1 high
limit value
OFF
OFF(4mA)
or
OFF
OUT1 low
limit value
Control range
–205.0 to 450.0
–209.0 to 850.0
–210.0 to 900.0
–210 to 900
–211.0 to 1099.9
–318 to 1600
–206.0 to 550.0
–207 to 550
–211.0 to 999.9
–312 to 1000
(100 )
OUT1
Reverse
OFF (4mA)
or
OUT1 low
limit value
ON (20mA)
or
OUT1 high
limit value
" for 4 to 20mA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents