Safety Information for the Electrician
-
Within the electrical installation an equipment is to be provided, which permits to disconnect the
appliance from the mains with a contact opening width of at least 3 mm at all poles. Suitable
separating devices are e.g. LS-switches, fuses (screw fuses have to be removed from their fuse
bases), FI-switches and contactors.
-
This appliance conforms to the type Y (IEC 335-2-6) referring the protection against danger of fire.
Only appliances of this type are allowed to be built in with one side next to high cabinets or walls.
-
Drawers must not be assembled beneath the cooking surface.
-
The touch protection must be guaranteed by the installation.
-
The stability of the built-in cabinet must meet DIN 68930.
-
Built-in ranges and built-in cooktops are equipped with special connection systems. They are only
to be combined with appliances of the matching system.
-
For the protection against moisture all sawed-out cut surfaces have to be sealed with suitable
sealing compound.
-
With tiled worktops the joints in the bearing surface of the cooking surface must be filled completely
with joint sealer.
-
With natural, artificial stone or ceramic cooking surface the snap-on springs have to be glued in
with a suitable resin- or two-pack glue.
-
Check the sealing in the bearing surface for perfect and complete seat. It is not allowed to apply
additional silicone sealing compound, which makes a disassembly difficult if a maintenance service
is needed.
-
The cooktop must be pressed out from below for disassembly.

Electric Connection

Before the connection check whether the mains voltage of the appliance, which is that voltage given on
the nameplate, agrees with the existing mains voltage. The nameplate is on the lower panel of the
cooking surface. The heating element voltage is AC230 V ~. Even with older mains supplies with AC220
V ~ the appliance works perfectly. The mains connection of the cooking surface has to be designed so
that all poles can be separated by a contact opening width of at least 3 mm, e.g. by LS switch, FI switch
or fuse. A line typed H05VV-F or higher has to be used as mains connection line. The mains connection
clamp is in the bottom of the cooking surface below a lid. By means of a screwdriver you can open the lid
(figure). The connection must be made according to the diagram. Depending on the connection diagram
the connection bridges have to be used accordingly. The protective conductor is connected by a clamp.
The core of the protective conductor must be longer than current-leading cores.
Cable connections have to be carried out according to requirements and the terminals must be tightened
firmly.
In the end the connection line must be secured with the tensile relieving clamp and the lid closed by firm
pressing (locking).
Before the first switching on possibly existing protective foils or stickers have to be removed from the
ceramic-glass surface or the frame.
After connection of the power supply switch on one cooking zone after the other in maximum
position for a short time to check the operability.
TSE-N 01.00 A. B.