Tap the Desiccant Warning tab.
3.
Desiccant Warning Applet Screen
Figure 3-35
Select a mode of operation (for example: Mode 1 can be set to work in a warehouse and Mode 2 for outdoors).
4.
Set the following parameters:
5.
• Enable periodic state update: enable periodic sample of humidity.
• Periodic state update rate: the number of seconds between two consecutive samples.
• Max Duration closer to DP for warning: the upper and lower temperature limits.
• Max DP reach cycles for warning: required number of events to issue a warning.
• Reaching DP threshold table: threshold values of humidity reports.
• Hysteresis table: hysteresis values to avoid rapid state switching initiating humidity reports.
Tap
to save changes.
6.
Apply
Operating the VC70 3 - 31