Ensure the cable length from the Ethernet source (host) to the Power Injector and access
point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch.
The Power Injector receives power and is ready for AP-7131 device connection and
operation as soon as AC power is applied. Refer to the Installation Guide shipped with the
Power Injector for a description of the device's LED behavior.
3. Verify all cable connections are complete before supplying power to the access point.

2.7 Mounting an AP-7131

The AP-7131 can attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or attic).
Choose one of the following mounting options based on the physical environment of the coverage
area. Do not mount the AP-7131 in a location that has not been approved in a site survey.
Refer to the following, depending on how you intend to mount the AP-7131:

Wall Mounted Installations

Suspended Ceiling T-Bar Installations
Above the Ceiling (Plenum) Installations
2.7.1 Wall Mounted Installations
Wall mounting requires hanging the AP-7131 along its width (or length) using the pair of slots on the
bottom of the unit and using the AP-7131 mounting template for the screws.
CAUTION An AP-7131 should be wall mounted to concrete or plaster-wall-board
!
The hardware and tools (customer provided) required to install the AP-7131 on a wall consists of:
• Two Phillips pan head self-tapping screws (ANSI Standard) #6-18 X 0.875in. Type A or AB
Self-Tapping screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping
screw
• Two wall anchors
• Wall mount template (included on next page)
• Security cable (optional)
To mount the AP-7131 on a wall using the provided template:
(dry wall) only. Do not wall mount an AP-7131 to combustible
surfaces.