Toro Groundsmaster 4000?D Service Manual page 101

Hide thumbs Also See for Groundsmaster 4000?D:
Table of Contents

Advertisement

PRELIMINARY – For Toro Distributor and Toro Company use only.
Removal (Fig. 48)
NOTE: The ports on the manifold are marked for easy
identification of components. Example: P1 is a piston
pump connection port and 2 is the location for the sole-
noid valve (See Hydraulic Schematic in Chapter 9 −
Foldout Drawings to identify the function of the hydraulic
lines and cartridge valves at each port).
1. Read the General Precautions for Removing and
Installing Hydraulic System Components at the begin-
ning of the Service and Repairs section of this chapter.
2. Disconnect electrical connector from the solenoid
valve.
3. Disconnect hydraulic lines from manifold and put
caps or plugs on open hydraulic lines and fittings. Label
disconnected hydraulic lines for proper installation.
4. Remove hydraulic manifold from the frame using
Figure 48 as guide.
Groundsmaster 4000−D
Installation (Fig. 48)
1. Install hydraulic manifold to the frame using Figure
48 as guide.
2. Remove caps and plugs from fittings and hoses.
Properly connect hydraulic lines to manifold.
3. Connect electrical connector to the solenoid valve.