4 Troubleshooting Malfunctions

4.1 Troubleshooting by Malfunction

If you are removing or mounting any of the sensors, be sure to pay attention
to the orientation/position of the spring used to keep the detecting lever in
place.

4.1.1 E000

Thermistor
1) Reset E000, and turn off and then on the power switch. Make the
YES: The cause is in the thermistor. Check the following:
DC controller PCB
2) Turn off the power switch, and let the fixing upper roller cool suffi-
YES: Replace the DC controller PCB.
Heater (open circuit), AC driver (triac; faulty)
3) Is the electrical continuity of each heater normal?
NO:
YES: Check the wiring; if normal, replace the AC driver PCB.
COPYRIGHT© 2001 CANON INC.
following selections in service mode:
COPIER>DISPLAY>ANALOG. Do readings of both <FIX-C> and
<FIX-E> indicate an increase in temperature?
I
thermistor for how it is mounted
I
thermistor for dirt on its surface
I
connection
ciently. Then, turn on the power switch. Reset E000, and turn off
and then on the power switch. Make the following selections in ser-
vice mode: COPIER>I/O>DC-CON. Are bit 0 and bit 1 of IO-P012
'0'?
Replace the heater.
2000 2000 2000 2000
CHAPTER 6 TROUBLESHOOTING
CANON iR105 REV.0 JULY 2001
6-87