3.2.4

Scanner related adjustment

[A] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON
(2)
Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3)
Press the [INTERRUPT] button to enter the normal mode.
(4)
Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5)
Press the [INTERRUPT] button to enter the adjustment mode.
(6)
Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(7)
Check if the distance A is within the range of 260±0.5 mm.