Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Classifi-
Code
cation
276
User
Default setting for density
interface
adjustment
281
User
Default setting of resolution
interface
283
User
Default setting of original
interface
mode
284
User
Default setting of scanning
interface
mode
285
User
Default setting of rotation
interface
angle of original
286
User
Default setting of original
interface
paper size
288
General
Searching interval of delet-
ing expired flies and check-
ing capacity of HDD
partitions
290
Network
Raw printing job (Duplex)
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Default
Func-
<Accept-
Items
tion
value>
SCN
SCN
SCN
SCN
SCN
SCN
<0-22>
ALL
<1-24>
PRT
2 - 163
07/11
RAM
Contents
able
0
SYS
0: Automatic density
<0-11>
1: Step -5
2: Step -4
3: Step -3
4: Step -2
5: Step -1
6: Step 0 (center)
7: Step +1
8: Step +2
9: Step +3
10: Step +4
11: Step +5
(1 to 11: Manual den-
sity)
1
SYS
0: 150 dpi 1: 200 dpi
<0-4>
2: 300 dpi 3: 400dpi
4: 600 dpi
0
SYS
0: Text
<0-3>
1: Text/Photo
2: Photo
3: Gray scale
0
SYS
0: Single 1: Book
<0-2>
2: Tablet
0
SYS
0: 0 degree
<0-3>
1: 90 degrees
2: 180 degrees
3: 270 degrees
0
SYS
0: Automatic
1: A3
3: LD
5: A4-R
7: LT-R
9: B4
11: ST-R 12: COMP
13: B5-R 14: FOLIO
15: 13"LG
16: 8.5" x 8.5"
18: A6-R
19: Size mixed
20: 8K
22: 16K-R
12
SYS
Sets the search inter-
val of deleting expired
files and checking
capacity of HDD parti-
tion.
(Unit: Hour)
*
Related code 08-
271
1
SYS
0: Valid
<0-1>
1: Invalid
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
1
1
1
1
1
1
2: A4
4: LT
6: A5-R
8: LG
10: B5
21: 16K
1
1
2