(5)
Remove the processing tray.
(6)
Loosen the screw on the home position sen-
sor plate at the front.
(7)
Adjust the position of the front jogging plate
home position sensor (S6) with reference to
the index.
EX. 1
If the width is 319 mm in step (4), the dif-
ference from the standard is +2 mm, it
requires relocation of the sensor in the
direction of arrow A by 2 mm.
EX. 2
If the width is 316 mm in step (4), the dif-
ference from the standard is -1 mm; it
requires relocation of the sensor in the
direction of arrow B by 1 mm.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Screw
Fig. 3-112
A
B
Sensor
Fig. 3-113
e-STUDIO200L/202L/203L/230/232/233/280/282/283
3 - 85
Home position
sensor plate