Alert report messages and actions
After the installation of WebPAM PRO, the following messages registered with the name
"Promise Event Logger" are set as reported sources. To change the setting, redefine it by using
the report setting feature of the NEC ESMPRO Agent.
Event
Message
ID
Battery temperature is above
512
the threshold
Battery is charging
517
526
Battery is not accessible
The write policy of writeback
logical drive switched from
529
writeback to writethru
The write policy of writeback
logical drive switched from
530
writethru to writeback
Logical drive initialization marks the
4101
logical drive offline
Logical Drive Initialization is
aborted due to an internal
4102
error
Quick Logical drive initialization
4108
marks the logical drive offline
Quick
Logical
Initialization is aborted due to
4109
an internal error
Logical drive has been placed offline.
4611
Possible Data Loss
4612
Logical drive has been set to critical
Media Patrol is aborted due to
5638
an internal error
6658
Physical Disk is marked as DEAD
Physical Disk has been reset
6659
Physical
Disk
6667
removed
Bad
sector
6671
physical disk
Previously configured disk is no
6675
longer found
A physical disk has encountered PFA
6677
condition
Physical Disk is marked as DEAD
6682
due to removal
Physical Disk is marked as DEAD
6683
due to the failure of Reassign
Action
No action required if the ID 517 message has not been
registered within 8 hours. If there is no ID 517 message,
the battery is required to be replaced.
This is for checking the ID 512 message.
Failure detected in battery. Check the battery and its life
duration and replace it if any failure exists or it has little
time left to live.
Check the battery if any failure exists.
Check the battery if any failure exists.
An array became offline. Please replace the failed HDD
and contact the customer or sales engineer for
reconstruction..
Check HDD and cables and replace it if any failure exists.
An array became offline. Please replace the failed HDD
and contact your customer engineer for reconstruction..
Drive
Check HDD and cables and replace it if any failure exists.
An array became offline. Please replace the failed HDD
and contact the customer or sales engineer for
reconstruction.
Physical drive became critical. Please replace the failed
HDD and execute rebuilding. If array has hot-spare drive,
rebuilding will be executed automatically.
Check HDD and cables and replace it if any failure exists.
Replace the failed HDD.
Check HDD and cables and replace it if any failure exists.
has
been
Physical driver has been removed. Check HDD and cables
and replace it if any failure exists.
is
found
on
Replace the HDD with bad sectors.
Replace the failed HDD.
Replace the failed HDD.
Replace the failed HDD.
Replace the failed HDD.
-
-
77