Event
Message
ID
Physical Disk is marked as DEAD
6684
due to PFA condition of the disk
Physical Disk is marked as DEAD
6685
due to forced offline state
RAID
migration
encountered a physical disk
6149
error
RAID
migration
encountered a physical disk
6150
error
Array was made Incomplete
6154
due to missing NV Watermark
Rebuild is completed
7681
Rebuild is paused
7682
Rebuild is resumed
7683
Rebuild is stopped
7684
Rebuild is aborted due to an
7687
internal error
Rebuild is queued
7689
Auto rebuild can not start
7696
Rebuild stopped internally
7697
Redundancy check is aborted
1542
due to an internal error
Redundancy
encountered
1543
block(s)
Redundancy check task is
1546
stopped internally
8192
SMART error is received
The above table shows the event IDs in decimal. The events listed in the table are reported to
NEC ESMPRO Manager. The symbols such as %1 in messages are padding characters.
Action
Replace the failed HDD.
Replace the failed HDD.
has
Physical disk error detected. If it cannot be fixed, replace
the HDD.
has
Migration aborted. Please contact the sales representative
for reconstruction of the array.
An error occurs during Migration. Please contact the sales
representative for reconstruction of the array.
Rebuild is completed. Check the status of the logical drive.
Rebuild is stopped. Restart rebuilding as soon as possible.
No specific action required.
Rebuild is stopped. Restart rebuilding as soon as possible.
Rebuilding aborted. Please contact the sales representative.
No specific action required.
The capacity of unconfigured physical drive is not capable
of rebuild. Replace a drive with proper capacity.
Rebuilding aborted. Please contact the sales representative.
Check HDD and cables and replace it if any failure exists.
check
If any error occurs in HDD, replace that HDD. If no error
inconsistent
occurs in HDDs, back up the system data and replace all
the HDDs.
Check HDD and cables and replace it if any failure exists.
Replace the failed HDD.
-
-