1.6.2 Precautions for Cabling

• Do not wire the cable with an AC cable, computer, etc.
• Do not run the cable near a high frequency generating device.
• Use cable protectors in case the cables are run on the floor.
• Aerial distribution wiring is not allowed.
• Trunks must be installed with lightning protectors.
• Do not install the Topaz Terminal in the SL system, it does not work properly.

1.6.3 Trunk Cabling

Ensure all Main and Expansion KSU(s) are powered off and unplug the AC
cord.
1.
Open the Sub-Cover.
Hardware Manual
Sub-Cover

Figure 2-20 Sub-Cover Open and Hold

SL1000
Push to hold
Open
2-15