Figure 2-3 Vertical Arrangement Of Ksus - NEC SL1000 Hardware Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 3.0
Minimum 200 mm (7.874)
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 300 mm (11.811)
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 200 mm (7.874)
• Due to the limit of extension cable length to connect Main KSU and Expansion KSU(s), the install
location of Main KSU and each Expansion KSU(s) must be considered as above or as the next figure.
• When KSU is mounted on the Battery Box, it cannot be wall-mounted for vertically as above.
• In the case, the KSU is mounted on Battery Box must be wall-mounted horizontally as shown on the
Figure 2-4 Horizontal Arrangement of KSUs on page
Hardware Manual
Ceiling
for ventilation
EXP. KSU
Main KSU
EXP. KSU
EXP. KSU
for wiring
Floor

Figure 2-3 Vertical Arrangement of KSUs

Minimum 300 mm (11.811)
2-6.
SL1000
Wall
2-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1000

Table of Contents