Recording the picture manually

Basic manual recording

This function is to setup the recording parameters of recording
setting pattern A to start recording manually. Ensure all the
cameras are connected and time and date has been set
correctly. Before you start recording, check the repeat recording
settings in the <Data Management Setting for Main Memory>
(System Menu
Memory Data Management Setting for Main
Memory) first, and then make the recording settings.
Make the manual recording settings on the <Set Recording
Pattern A (Normal/Timer)> (Setup Menu Recording Set
Recording Pattern A (Normal/Timer)).
<Set Recording Pattern A (Normal/Timer)> can be used
for manual or timer recording. <Set Recording Pattern B
(Timer)> to <Set Recording Pattern D (Timer)> are used
for timer recording only.
Settings here are for manual recording only. For timer
recording, settings must be made on the <Timer> menu
(Setup Menu Timer).
Setup Menu
1
Recording
Set Recording Pattern A (Normal/Timer)
1
1
Camera Check
Recording Setting A-Normal (Auto)
2 + D
D
2 + D
Recording Setting A-Normal (Easy)
D
Recording Setting A-Normal (Manual)
2 + D
D
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
16
Recording Setting A-Normal
Recording Setting A-Normal
Recording Setting A-Normal
Setting the recording rate and picture grade for
normal recording
1. Execute camera check.
step
• The unit automatically detects the cameras with
video signal at their input when you select
"Execute." The detected cameras are used in the
Auto and Easy settings calculation in step 2.
After executing the camera check, the recording settings
are made only for the camera numbers with the video signal
input when using auto or easy setting.
2. Set the normal recording menu.
step
Auto: Automatically sets the picture grade and the
recording rate by setting the recording cycle and
the recording hour per day. Set the desired settings
and then select "Execute."
• The preview screen appears automatically when
the auto setting is executed.
Easy: Sets the frame or field recording, recording
rate, and picture grade for normal recording to the
same settings for all the cameras. When the
recording rate is set to "– – –" for all the camera
numbers, normal recording does not perform. Set
the desired settings and then select "Execute."
• The preview screen appears automatically when
the easy setting is executed.
Manual: Sets per camera, the frame or field
recording, recording rate, and picture grade for
normal recording. When you set "– – –" for the
1
recording rate, the recording does not perform for
step
that camera number.
• Select "View" to display the preview screen and
2
check your settings.
step
When you set frame recording, the recording rate display
in the preview screen turns green.
The recording rate display turns red when the value
exceeds 200 pps in total.
<Estimated Recording Time>
The estimated continuous recordable time is displayed on
the bottom of the preview screen which is dependent on
the picture grade and the recording rate settings for normal
recording. (The time does not reflect alarm recording
settings.)
When the main device is partitioned, <Estimated Recording
Time> shows the estimated recordable time for normal
recording.
3. Press the REC/STOP button.
step
• The REC/STOP button lights up and recording
starts.
4. To stop recording, press the REC/STOP button for
step
more than 2 seconds.
• Recording stops and the light turns off.
REC/STOP