(2) Remove the cap from the developer bottle and
install the nozzle (service jig) to the bottle.
Pour the developer material into the developer
unit.
(3) After pouring in the developer material, rotate
the gear in the direction of the arrow as shown
to deliver the developer material onto the mag-
netic roller.
(4) Reinstall the top cover; after inserting the hooks
(4 places) firmly, fix the plate spring hooks by
rotating in the direction of arrow A securely.
1550/1560 DEVELOPER
10 - 4
Nozzle
A
Plate spring hooks