5.1. Example of the inverter status reading

The following explains a program to read the inverter status from master unit buffer
memory.
The following program reads the inverter status of station 2 to M0 – M7 register.
X0000
X000F
X0001
Address of master
Remote Input
unit buffer memory
 RX0 ∼ RXF
E0H
Station 1
E1H
RX10 ∼ RX1F
RX20 ∼ RX2F
E2H
Station 2
RX30 ∼ RX3F
E3H
15EH
RX7E0 ∼RX7EF
Station 64
RX7F0 ∼RX7FF
15FH
[ FROM H0000 H00E2 D0 K1 ]
[ MOV D0 K2M0 ]
FROM
b15
instruction
0 0
D0
Note *: 0 or 1 because of reserved bits.
Inverter Status
M0 : Forward running
M1 : Reverse running
M2 : Output terminal function selection 1
M3 : Output terminal function selection 2
M4 : Output terminal function selection 3
M5 : Output terminal function selection 4
M6 : Output terminal function selection 5
M7 : Output terminal function selection 6
21  −
− 
Reads the remote input data buffer
memory to D0.
Stores b0 – b7 (status) in D0 to
M0 – M11.
b8 b7
0
0
*
0
0
0
0
0
[RX2F to RX28]
M7 M6 M5 M4 M3 M2 M1 M0
0
0
Inverter Status
Example: The above indicates
E6581288①
b0
0
0
0
0
0
1
[Inverter Status]
Forward running
  
MOV instruction
0
0
0
0
0
1
forward running.