5.8. Example of the trip history reading

The following program reads the trip history of station 2 inverter to D1.
Trip history No.1, No.2 reading code number :74H (Hexadecimal number)
To reply code at the time of instruction code execution is set to D2.
M9036
X0000 X000F X0001
M302
Read setting
M303
M115
M9036
Sample of the display of trip history
Read data ............ Case of 2D0EH.
b15
0
   e-13(Error code: 2DH)
   "Speed error (Over speed)"
*For details of error code, refer to "Section 4.4.4. The details of an error code".
[ FROM H0000 H00E2 K4M100 K2]
X0020
[ TO H0000 H01E6 D100 K1]
[ FROM H0000 H02E7 D1 K1]
[ FROM H0000 H02E6 D2 K1]
[ TO H0000 H0162 K4M200 K2]
0
1
0
1
1
0
  (2DH)
 Trip of last time
[ PLS
M302]
[ SET
M303]
[ MOV H0074 D100]
[ SET
M215]
[ RST
M215]
[ RST
M303]
b8 b7
1
0
0
0
0
1
     (0EH)
Trip of this time
  ol2(Error code: 0EH)
"Motor overload"
26  −
− 
E6581288①
Reads the remote input (RX20 to RX3F)
data of buffer memory to M100 – M131.
Write trip history N0.1, No.2 reading code
(74H) to RWw6.
Switches on the instruction code execution
request (RY2F).
Reads trip data (RWr7) and reply code (RWr6)
to D1 and D2 when the instruction code
execution completion (RX2F) switches on.
Switches off the instruction code execution
request (RY2F).
Writes M200 – M231 data to the remote outputs
(RY20 to RY3F) of buffer memory.
b0
1
1
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-as1 cc-linkCcl001z