Func.
Name
Code
p039
Speed limit of
Torque control
(Forward rotation)
p040
Speed limit of
Torque control
(Forward rotation)
p041
Speed / Torque
control switching
time
P044
Communication
watchdog timer
(for option)
P045
Inverter action on
communication
error
(for option)
P046
DeviceNet polled
I/O:
Output instance
number
P048
Inverter action on
communication
idle mode
P049
Motor poles
setting for RPM
p055
Pulse train input
frequency scale
setting
p056
Pulse train input
frequency filter
time constant
setting
p057
Pulse train input
bias setting
p058
Limitation of the
pulse train input
setting
p059
Lower cut off level
*2
of the input pulse
P060
Multistage position
0
P061
Multistage position
1
P062
Multistage position
2
P063
Multistage position
3
P064
Multistage position
4
P065
Multistage position
5
P066
Multistage position
6
P067
Multistage position
7
"P" Function
Description
Set range is 0.00 to 120.00Hz
Set range is 0.00 to 120.00Hz
Set range is 0 to 1000 ms
Set range is 0.00 to 99.99s
00...Tripping
01...Tripping after decelerating and
stopping the motor
02...Ignoring errors
03...Stopping the motor after free-running
04...Decelerating and stopping the motor
00 to 20
00...Tripping
01...Tripping after decelerating and
stopping the motor
02...Ignoring errors
03...Stopping the motor after free-running
04...Decelerating and stopping the motor
0/2/4/6/8/10/12/14/16/18/20/22/24/
26/28/30/32/34/36/38/40/42/44/46/48
Sets the pulse numbers at max.
frequency, set range is 1.0~32.0 kHz
Set range is 0.01 to 2.00 sec.
Set range is –100 to 100 %
Set range is 0 to 100 %
0.01 to 20.00[%]
P073 to P072
(Displayed higher 4-digits only)
92
Defaults
A
B
Initial data
0.00
0.00
0.
1.00
00
01
00
0
1.5
0.10
0.
100.
1.00
0
0
0
0
0
0
0
0
Units
Hz
Hz
ms
s
Poles
kHz
s
%
%
%
Pulses
Pulses
Pulses
Pulses
Pulses
Pulses
Pulses
Pulses