Hitachi wj200 series Quick Reference Manual page 95

Hide thumbs Also See for wj200 series:
Table of Contents

Advertisement

Func.
Name
Code
P200
Serial
communication
*2*3
mode
p201
to
Modbus external
P210
register 1 to 10
*2*3
p211
to
Modbus register
P220
format 1 to 10
*2*3
p221
to
Modbus register
P230
scaling 1 to 10
*2*3
p301
to
Modbus internal
P310
register 1 to 10
*2*3
P400
Modbus endian
*
setting
*2*3
P900
Single-phase
*4
encoder pulse
input half cycle/
whole cycle select
P901
Filter time
*4
constant for
speed detection
*1
: Up to 580Hz for high frequency mode (b171 set to 02)
*2
: Available from version 3.0
*3
: Power cycle is required to reflect a change.
*4
: Available from version 3.1
"P" Function
Description
00...Standard
01...Free mapping
0000h to FFFFh
00...Unsigned
01...Signed
0.001 to 65.535
0000h to FFFFh
00...Big endian
01...Little endian
02...Special endian*3
Two options; select codes:
00...Half cycle
01...Whole cycle
Set range is 0 to 9999 msec
95
Defaults
A
B
Initial data
00
0000
00
1.000
0000
00
00
20.
Units
%
ms