Mitsubishi Electric QD77MS User Manual page 102

Simple motion module
Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

[Cd.609] Cam auto-generation cam No.
Set the cam No. to be generated automatically.
[Cd.610] Cam auto-generation type
Set the type of cam auto-generation.
[Cd.611] Cam auto-generation data
Set the cam auto-generation data corresponding to "[Cd.610] Cam auto-generation type".
1) For a rotary cutter
The cam data starting point for a rotary cutter is 0.
Buffer memory
address
53204
Cam resolution
53206
Sheet length
53207
Sheet
53208
synchronization
53209
width
53210
Synchronous axis
53211
length
53212
Synchronization
53213
starting point
Synchronous
53214
section acceleration
ratio
Item
Setting value
256/512/1024/2048/
4096/8192/16384/32768
1 to 2147483647
[(Optional) Same unit
(0.1mm, etc.)]
1 to 2147483647
[(Optional) Same unit
(0.1mm, etc.)]
1 to 2147483647
[(Optional) Same unit
(0.1mm, etc.)]
0 to 2147483647
[(Optional) Same unit
(0.1mm, etc.)]
-5000 to 5000 [0.01%]
3 - 18
Chapter 3 Cam Function
Details
Set the cam resolution for generating the
cam.
Set the sheet length.
Set this value in the cam axis length per
cycle.
Set the sheet length of the synchronous
section.
Set the cycle length of the rotary cutter
shaft.
Set the length from the beginning of the
sheet to the start of the synchronous
section.
Set when the synchronous speed in the
synchronous section needs to be adjusted.
The speed is "Synchronous speed
(100% + Acceleration ratio)" in the
synchronous section.

Hide quick links:

Advertisement

Table of Contents
loading