Panasonic KV-S1025C SERIES Service Manual page 72

High speed color scanner
Table of Contents

Advertisement

Item
Individual Position 1. Adjust Automatically
a. Set Test Chart A4 (Part No.: See 14.3.) on the Feed Tray
b. Click "Individual Position" on the main menu.
c. Click one of 8 automatic adjustment menu on the
"Individual Position" dialog box to execute the
adjustment.
d. Check the result.
e. Click "OK" to finish this adjustment.
f. Click "OK" to get back to the main menu.
2. Adjust Manually
a. Click "Individual Position" on the main menu.
b. Change the parameter (mm, %) on the "Individual
c. Click "OK" to apply the new setting, and to get back to the
*USB ID
1. Click "USB ID" on the main menu to go into the USB ID
dialog box.
2. Click "Set" on the USB ID dialog box to store a new ID
number for a new replaced CONTROL Board.
3. Click "Close" to go back to the main menu.
9.3.8.
Other (Save Information)
Clicking "Save Info" on the main menu enables the PC to save the scanner and the PC information as text files.
Operation
in the portrait orientation, according to
"1. Adjust Automatically" in the Remarks column.
Position" dialog box, as required. (Refer to Remarks.)
main menu.
Default
72
Remarks
1. Adjust Automatically
8 automatic adjustment
(1) Adjust Length.
(2) Adjust Paper-end Position.
(3) Adjust Front Width.
(4) Adjust Front V. Position.
(5) Adjust Front H. Position.
(6) Adjust Back Width.
(7) Adjust Back V. Position.
(8) Adjust Back H. Position.
(1) to (5): Face down the chart
on each individual
adjustment.
(6) to (8) : Face up the chart on
each individual
adjustment
(KV-S1025C Series Only)
2. Adjust Manually
(Length)
+: Increasing a value allows
the scanning image to
extend vertically.
(Paper End Position)
+: On the LC (Length Control)
mode, increasing a value
allows the paper-end timing
to be earlier.
(Width)
-: Decreasing the value
narrows the document width.
(Vertical Position)
+: Increasing the value shifts
the document image position
downward.
(Horizontal Position)
+: Increasing the value shifts
the document image position
to the right.
Note:
If the appropriate
scanning position can not
be obtained by any of the
manual adjustments, check
the Optical Unit
installation.
* This setting is available only
for a new replaced
CONTROL Board.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kv-s1020c series

Table of Contents