10.3.4
Ethernet setting
Item
Host
N/W No.
*1
Station
Type
IP Address
Port No.
Communication format
*1
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
➠
10.3.2 Communication detail settings
Description
The host is displayed.(The host is indicated with an asterisk (*).)
Set the network No. of the connected Ethernet module.
(Default: blank)
Set the station No. of the connected Ethernet module.
(Default: blank)
SLMP (fixed)
Set the IP address of the connected Ethernet module.
(Default: blank)
Set the port number of the SLMP compatible device.
(Default: 49152)
UDP, TCP
(Default: UDP)
Range
―
1 to 239
1 to 120
―
SLMP equipment side IP address
1 to 65535
Adjust the setting with the communication
format of the SLMP compatible device.
10.3 GOT Side Settings
10
10 - 7