20.4.2
Communication detail settings
Make the settings according to the usage environment.
■1. Video Setting
Item
*1
Video Input Signal
*2
Video Resolution
*1
*2
■2. IP Address Setting for Multimedia Unit
Set the network settings for connecting from the multimedia unit via Ethernet.
Item
IP Address
Subnet Mask
Default Gateway
20 - 8
20.4 GOT Side Settings
Set the video input signal.
(Default: NTSC)
Set the video resolution.
When NTSC format is selected, the resolution is fixed to 640 480.When PAL format is selected, the resolution is fixed to
768 576.
For GT2710-V and GT2708-V, the resolution is fixed to 640 480.
Set the IP address of the multimedia unit.
(Default: 192.168.3.51)
Set the subnet mask for the sub network. (Only for connection via
router) If the sub network is not used, the default value is set. (Default:
255.255.255.0)
Set the router address of the default gateway on the side to which the
multimedia unit is connected. (Only for connection via router)
(Default: 0.0.0.0)
POINT
POINT
POINT
Network settings with the utility
The network setting can be changed on the Utility's [Communication setting] after writing
[Controller Setting] of project data.
For details on the Utility, refer to the following manual.
➠
GOT2000 Series User's Manual (Utility)
Description
Description
Range
NTSC, PAL
640 480,
720 480,
768 576
Range
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255