7.6 PROFIBUS DP master equipment Side Settings

This section explains how to set the PROFIBUS DP master
equipment.
POINT
POINT
POINT
PROFIBUS DP master equipment
For the details of the PROFIBUS DP master
equipment setting method, refer to the manual of the
used PROFIBUS DP master equipment.
Installing the GSD file for GOT
Install the GSD file for GOT to the configuration tool on
the PROFIBUS DP master equipment side, and set the
GOT as slave equipment.
For how to acquire the GSD file for GOT, refer to the
following.
7.5 Preparation of GSD File for GOT
Communication configuration
Set the following communication parameters using the
configuration tool on the PROFIBUS DP master
equipment side.
Item
*1
Station No.
Master
Transmission
equipment
speed
*1*2
Station No.
Slave
equipment
Device setting
*1
Make sure that the station No. does not overlap.
*2
Align the setting of "Station No." on the GOT side with the
station No. of the slave equipment.
7.4 GOT Side Settings
Setting range/Setting method
0 to 125
9.6kbps
19.2kbps
45.45kbps
93.75kbps
187.5kbps
500kbps
1.5Mbps
12Mbps
0 to 125
For the setting method, refer to
the following manual.
Manual of PROFIBUS
DP master equipment

7.6 PROFIBUS DP master equipment Side Settings

7. PROFIBUS DP CONNECTION
7
7 - 7