12.95
Module type
DMP compact module 16I
DMP compact module 16O
DMP compact module 8O
DMP compact module 1I analog
DMP compact module 1I NC
analog IN
DMP compact module 1O analog
Placement in max. of two terminal blocks of a control:
Important
!
A maximum of four analog outputs and four analog inputs can be connected to
each NCU terminal block at any one time.
Caution
!
If the load supply voltage for the DMP compact modules is switched off during
operation, the outputs will not switch through reliably when the load supply
voltage is switched on again. If switching off during operation cannot be
avoided, the DMP outputs must be reset via the PLC program. The outputs
must be set anew after the voltage has been switched on again.
S
Monitoring
functions
S
S
S
S
Undervoltage
(< 4.75V)
Ambient temperature
NCU sign-of-life
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
I/Os
Digital inputs
Digital outputs
Analog inputs
Analog outputs
+5V monitoring
Temperature monitoring 60_C 3_C
Configuration level monitoring
Microcontroller sign-of-life monitoring (watchdog)
NC sign-of-life monitoring (watchdog).
Error
Limit value signal
Temperature sensor
Cyclic message
7 NCU Terminal Block
Max.
Variation
number
2
Digital inputs
2
Digital outputs 0.5A
4
Digital outputs 2.0A
8
Analog input 13 bits
4
High- -speed analog input 75μs,
12 bits
4
Analog output 14 bits
Number
32
32
8
8
Recording
Disabling of the NC outputs,
LED (green) off
Status message to NC,
Screen display
Disabling of the NC outputs,
LED (red) on
Effect
7-99