2 Installation Conditions

2.2 Ambient climatic and mechanical conditions

2.2
Ambient climatic and mechanical conditions
2.2.1
Transport and storage conditions
Relevant
IEC 68-2-1, IEC 68-2-2, IEC 68-2-3
standards
Components in
The following specifications apply to components in transport packaging:
original packaging
Table 2-7
Temperature range
Relative air humidity U
Temperature change
Atmospheric pressure
Table 2-8
Vibratory load (according
to IEC 68-2-6)
Transportation of
Backup batteries must be transported in original packaging only. No special
backup batteries
approval is needed for transporting backup batteries. The lithium content is
approximately 300mg.
Note: The backup battery is classified in dangerous materials class 9 in
accordance with the relevant air-freight transportation regulations.
Applicable standards: DIN EN 60086(-4)
Warning
!
Improper handling of backup batteries involves the risk of ignition, explosion
and burning.
2-34
Climatic conditions
See technical data of the relevant component
Annual average
up to 30 days (24 hours) per
year
Within one hour
The values specified apply to
a transportation altitude of up
to 3265m above mean sea
level
Mechanical conditions during transportation in original packaging
Frequency range
5–9Hz
over 9–200Hz
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
U ≤75%
U ≤ 95%
< 10K
66kPa to 108kPa
Const. displacement
3.5mm
Ampl. of acceleration
2
9.8 m/sec
E Siemens AG, 2002. All rights reserved
11.02
12.95