Siemens SINUMERIK 810D Configuration Manual page 110

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

8 DMP Compact Modules
8.3 DMP compact module 8O (6FC5 111-0CA03-0AA1)
Table 8-3
Number of outputs
Floating
Supply voltage V
Signal level of outputs (typical value)
Output loading at "1" signal (rated value)
Short-circuit protection
Power loss at 30 V
Switching rate at
Total load capacity at 55
rated currents of all outputs)
Delay time
Delay time
Cable length
Weight
Degree of protection according to DIN 40050
Humidity rating according to DIN 40040
Four outputs are fed from one power supply. The sum of the output currents
must not exceed 4A for four outputs (outputs 0 ... 3 and 4 ... 7) (this corresponds
to a simultaneity factor of 50% at full load of the individual outputs).
All 8 outputs may be loaded simultaneously, e.g. with 1A.
Important
!
Switching surges must be neutralized by external free-wheeling diodes when
using inductive loads.
8-108
Technical data DMP compact module 8O
LOAD
- Rated value
- Permissible range
- Ripple
- For "0" signal
- For "1" signal
- Resistive load
- Lamp load
- Inductive load
- Resistive load
- Lamps
- Inductive load (at rated
load, higher values per-
missible at lower load)
¥
C (as referred to the sum of the
for tp
LH
for tp
HL
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
8 digital outputs
Yes
24VDC
20.4V to 28.8V
3.6Vpp
Open
V
- -80mV
LOAD
2000mA
25W
2000mA
Yes
Max. 3.1W
100 Hz
11 Hz
2 Hz
50%
tp
= max. 0.5msecs
LH
tp
= max. 0.5msecs
HL
max. 50m
approx. 145g
IP20
F
E Siemens AG, 2002. All rights reserved
12.95