Chapter 5
Component Expansion/Function Enhancement
5.2
Installing Additional Drive Enclosures
The connectors on the cable with the "n" symbol are connected to the DI (OUT) ports on the nearest
enclosure.
6
Connect the DI (IN) port of IOM#0 in the drive enclosure that is to be added to the DI (OUT) port of
IOM#0 in the nearest drive enclosure with the mini SAS HD cable between enclosures.
The following figure shows how the mini SAS HD cables between enclosures are connected when drive
enclosure 2 is added.
Drive enclosure 2
(drive enclosure
that is to be added)
Drive enclosure 1
7
Connect the power cord.
(1)
Connect the power cord to the drive enclosure.
Each enclosure has two (or four) power supply units. Make sure that the power cords are con-
nected to all the power supply units.
(i)
FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic)
Connect here
Connect here
Connect the power cord plugs to the power inlets of the power supply units.
Copyright 2017 FUJITSU LIMITED