2.6. Technical data

Max. operating pressure
Measuring technique
Operating temperature
Measured parameters
Sensor
Media
Humidity of medium
Power supply
Power consumption
Digital output
Analog output
Pulse output
Accuracy
Display/indicator
Screw fitting
Material
14
Technical data
SF53
16 bar, optional 50 bar
Calorimetric
Sensor tube and fittings: -30 ... +140 °C
Housing: -30 ... +80 °C
m³/h (factory settings)
On the display version, the following units can be chosen:
m³/min, l/min, l/s, ft/min, cfm, m/s, kg/min, kg/s
Pt45, Pt1000
nitrogen, argon, helium, carbon dioxide
max. 90 % rH (no droplets)
18 ... 36 VAC
max. 5 W
RS485 (Modbus RTU)
4 ... 20 mA (max. load < 500 Ω)
Floating switch contact
Passive: max. 48 VDC 150 mA
1 pulse per m³ or per litre
Unit adjustable at display
± 1.5 % of measured value
± 0.3 % of final value
Display: TFT 1.8" (resolution: 220 x 167) or service LED
G½ (ISO 228/1)
Sensor tube and fittings: 1.4301 stainless steel
Housing: Powder-coated aluminium
Flange: 1.4404 (DIN EN 1092-1)
EN