Fujitsu IP-900E Hardware User's Manual page 80

Hide thumbs Also See for IP-900E:
Table of Contents

Advertisement

Chapter 5 Troubleshooting
No. Class
Status
6.
Data
7.
communication
is disabled.
8.
9.
The INDWN
lamp lights in
orange.
10.
The INDWN
11.
lamp blinks in
orange.
12.
13.
14.
No images can
be output on the
15.
receiving device
(black screen).
16.
17.
18.
Blue/gray
screen is output.
19.
IP-900E/IP-900D/IP-900IID
Description
Is the port setting correct?
Is the data input/output device
operating normally?
Are this equipment and the
communication destination device
correctly connected?
Is the power to the video/audio
output device (such as a camera)
selected for input turned on?
Is this equipment correctly
connected to the video/audio
output device? (e.g. SDI signal
was connected to analog video
input of this equipment by
mistake.)
Are the specified input video/audio
format matched with video/output
device (such as camera) this
equipment correctly connected to
the video/audio output device?
(e.g. Although this equipment was
set as SD-SDI input setting,
HD-SD signal input was detected
by mistake.)
Are the specified input video/audio
format matched with video/output
device (such as camera) this device
correctly connected to the
video/audio output device?
(e.g. Although this equipment is
set as 59.94Hz, the output device
was set as 50Hz by mistake.)
Is the monitor which connects to
the receiving device working
normally?
Is the receiving device working
normally?
Is the receiving device and
monitor connected correctly?
Does alarm occur on the receiving
device?
Does a color bar or gray screen
appear on the receiving device
when image input of this
equipment is set to non-input?
(Since this operation generates an
alarm, obtaining the system
administrator's approval before
conducting this test.)
Is the RDY LED blinking?
Is the RDY LED turned on in
orange?
Is the ALM LED blinking?
Recommended action
Check the data input-output port settings.
⇒Refer to Software User's Guide.
Check the operation of the data input/
output devices.
Check cable connections between this
equipment and communication destination
equipment and the cable pin assignments.
Check the selected power supply of
video/audio output device and the
performance.
Check
the
equipment and video/audio output devices
correctly and whether the cable has
problems or not.
Check whether the format is set to the
using video/audio format for this
equipment and output device or not.
Check whether the format is set to the
using video/audio format for this
equipment and output device or not.
Check the power and operation of the
monitor.
Check the power and operation of the
receiving device.
Check connections between the receiving
device and the monitor.
If yes, refer to the user's guide of receiving
device and follow the instructions.
When color bar or the blue screen is
displayed, the network and receiving
device would be worked normally.
Check whether the correct image is input
in this equipment or not.
The hardware system is operating while
the RDY LED is blinking. Wait until the
LED remains on.
This equipment is started in the
maintenance mode.
Reboot this equipment.
ALM LED blinks when IP address
obtaining might be failed to get. Check IP
address setting (For more information,
refer to the Software User's Guide).
66
connection
between
this

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip-900dIp-900iid

Table of Contents