Fujitsu IP-900E Hardware User's Manual page 83

Hide thumbs Also See for IP-900E:
Table of Contents

Advertisement

Table 5.1.1 Problem descriptions and recommended actions(IP-900D/IP-900IID)
No. Class
Status
1
Power cannot be
turned on.
2
The ALM LED
3
is on.
The ALM LED
4
is blinking.
The LEDs
excluding LAN
5
are on.
6
Data
7
communication
is disabled.
8
9
10
No image can be
output on the
11
receiving device
(black screen).
12
13
Description
Is the power cable connected?
Is the outlet voltage normal?
Equipment error is occurred.
Settings/Performances of the
equipment and each error is
shown.
E013 Temperature warning
L009 DHCP connection failure
L00A PPPoE connection failure
Is the ambient temperature of this
equipment within the condition of
specification?
Do you secure indicated space in
the condition for air supply and
exhaust opening?
Is the port setting correct?
Is the data input/output device
operating normally?
Are this equipment and the
communication destination device
correctly connected?
Is the receiving device turned on?
Is the power of device turned on?
Is this equipment correctly
connected to the monitor?
Is the video output setting of this
device correct?
Is ALM LED turned on?
69
Chapter 5 Troubleshooting
Recommended action
Check the power cable is properly
connected to the outlet.
Measure the voltage with a tester and
check the voltage is normal.
When another device is connected to the
same outlet, check the other device's
performance.
Contact to CE in Fujitsu Service Center.
CE may ask the alarm code for checking
your status. Check each alarm code using
log information screen of Web GUI before
you contact to us.
Check alarm code using log information
screen of Web GUI. The countermeasures
are shown.
Check whether the condition is satisfied
with "2.1 Installation Conditions" or not.
- Do you secure certain space for air supply
and exhaust opening?
- Is ambient temperature within the
condition?
In case of having problems in the
conditions above, reboot the equipment
after excluding the all problems.
In case of not having any problems, contact
to Fujitsu CE because the equipment might
be failed.
Please refer to 41 of this table.
If yes, adjust the temperature within the
condition of specification.
⇒Refer to "2.1.1 Environment
Conditions".
If no, secure the space.
⇒Refer to "2.1.3 Air supply and exhaust
of the equipment".
Check the data input-output port settings.
⇒Refer to Software User's Guide.
Check the operation of the data input/
output device.
Check cable connections between this
equipment and communication destination
device and the cable pin assignments.
Check the power and operation of this
equipment on the receiving device.
Check that PWR LED lights.
Check the connection between device and
the monitor.
Check the video output setting of this
device allows the monitor to display.
Refer to clause 3 in this table.
IP-900E/IP-900D/IP-900IID

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip-900dIp-900iid

Table of Contents