Installing A Prru3901; Prru3901 Installation Kits - Huawei DBS3900 Installation Manual

Lampsite
Hide thumbs Also See for DBS3900:
Table of Contents

Advertisement

LampSite
Installation Guide
Figure 6-4 pRRU3901 installation process

6.4 Installing a pRRU3901

This section describes the pRRU3901 installation process. A pRRU3901 can be installed on a
wall, ceiling, indoor metal pole, or keel.

6.4.1 pRRU3901 Installation Kits

This section describes the pRRU3901 installation kits.
Issue 08 (2015-01-15)
NOTE
l The pRRU3901 cannot be grounded. If the pRRU3901 is grounded but the RHUB3908 connected to
this pRRU3901 is not, the pRRU3901 may fail to be powered on.
l A minimum distance of 50 cm must be reserved between the pRRU3901 and the incandescent lamp.
l The installation spacing between the pRRU3901 and the temperature sensor must be greater than 50
cm.
l It is good practice to install the pRRU3901 on materials that can tolerate a temperature higher than 65°
C and have an ignition point higher than 70°C.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 Installing a pRRU3901
58