Installation - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
System Hardware Manual
Basic PRI Call Control (BCC)
Display of incoming caller's name and number (when allowed by the
telco)
Speech and 3.1 KHz audio
When installed, CD-PRTA uses the first block of 32 consecutive trunk
ports. For example, if a COIU blade is installed for trunks 1~8, the
CD-PRTA automatically uses trunks 9~40. If the COIU blades are
installed for trunks 1~8 and 17~24, CD-PRTA uses trunks 25~56.
The CD-PRTA cannot use trunks 9~16 (even if available) since they
are not part of a consecutive block of 32 trunks. Each CD-PRTA
requires 32 ports in the system, even if not all the ports are used,
otherwise the blade does not function.
The CD-PRTA requires one universal slot.
Table 4-55 CD-PRTA Maximum Upgrade Capacities
maximum capacities for the CD-PRTA blades when they are
upgraded.
Table 4-55 CD-PRTA Maximum Upgrade Capacities
19" Chassis
with CPU
3
5.7.2

Installation

To install the CD-PRTA:
1.
Plug the CD-PRTA into any universal slot on the chassis.
2.
Use Program 10-51-01 (PRI/T-1) to set the CD-PRTA blade to
either PRI.
3.
Connect the cable from the NT1 Network Termination cable to
the CN2 connector on the CD-PRTA. (Refer to
19" Chassis
19" Chassis
without CPU
3
With normal operation, LED 1 flashes green.
Issue 7.0
provides the
Networked
x4
Chassis
6
8
Figure 4-30 PRI
4 - 99

Advertisement

Table of Contents
loading

Table of Contents