To display the user-defined MAC and WWN address, use the following RACADM command:
racadm getmacaddress -c io-identity
racadm getmacaddress -c io-identity -m server -2
To display the console assigned MAC/WWN of all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c all
To display the chassis assigned WWN/MAC address, use the following RACADM command:
racadm getmacaddress -c flexaddress
To display the MAC/WWN addresses for all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c factory
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM
command:
racadm getmacaddress -a
For more information on the getflexaddr and getmacaddress subcommand, see the Chassis Management Controller for PowerEdge
VRTX RACADM Command Line Reference Guide.

Command Messages

The following table lists the RACADM commands and output for common FlexAddress situations.
Table 35. FlexAddress Commands and Output
Situation
SD card in the active CMC module is
bound to another service tag.
SD card in the active CMC module that
is bound to the same service tag.
SD card in the active CMC module that
is not bound to any service tag.
FlexAddress feature not active on the
chassis for any reason (No SD card
inserted/ corrupt SD card/ after
feature deactivated /SD card bound to
a different chassis).
Guest user attempts to set FlexAddress
on slots/fabrics.
Deactivating FlexAddress feature with
chassis powered ON.
Guest user tries to deactivate the
feature on the chassis.
Command
$racadm featurecard -s
$racadm featurecard -s
$racadm featurecard -s
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
$racadm feature -d -c
flexaddress
$racadm feature -d -c
flexaddress
Output
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: bound to another
chassis, svctag = <Service tag
Number> SD card SN = <Valid
flex address serial number>
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: bound
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress:not bound
ERROR: Flexaddress feature is
not active on the chassis
ERROR: Insufficient user
privileges to perform
operation
ERROR: Unable to deactivate
the feature because the
chassis is powered ON
ERROR: Insufficient user
privileges to perform
operation
149