Configuring Ip Range Attributes Using Racadm; Configuring Virtual Lan Tag Properties For Cmc; Configuring Virtual Lan Tag Properties For Cmc Using Racadm - Dell EMC PowerEdge VRTX User Manual

Chassis management controller
Table of Contents

Advertisement

For more information, see the Online Help.
5.
Click Apply to save your settings.

Configuring IP Range Attributes Using RACADM

You can configure the following IP Range attributes for CMC using RACADM:
IP range checking feature
Range of IP addresses that you want to block from accessing CMC
IP Range Mask that you want to block from accessing CMC
IP filtering compares the IP address of an incoming login to the IP address range that is specified. A login from the incoming IP
address is allowed only if both the following are identical:
cfgRacTuneIpRangeMask bit-wise and with incoming IP address
cfgRacTuneIpRangeMask bit-wise and with cfgRacTuneIpRangeAddr
To enable the IP range checking feature, use the following property under cfgRacTuning group:
cfgRacTuneIpRangeEnable <0/1>
To specify the range of IP addresses that you want to block from accessing CMC, use the following property under
cfgRacTuning group:
cfgRacTuneIpRangeAddr
To specify the IP Range Mask that you want to block from accessing CMC, use the following property under cfgRacTuning
group:
cfgRacTuneIpRangeMask

Configuring Virtual LAN Tag Properties for CMC

Virtual LANfunctionality enables multiple VLANs to coexist on the same physical network cable and to segregate the network traffic
for security or load management purposes. When you enable the VLAN functionality, each network packet is assigned a VLAN tag.

Configuring Virtual LAN Tag Properties for CMC Using RACADM

1.
Enable the Virtual LAN (VLAN) capabilities of the external chassis management network:
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 1
2.
Specify the VLAN ID for the external chassis management network:
racadm config -g cfgLanNetworking -o cfgNicVlanID <VLAN id>
The valid values for <VLAN id> are 1– 4000 and 4021– 4094. Default value is 1.
For example:
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
3.
Then, specify the VLAN priority for the external chassis management network:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority <VLAN priority>
The valid values for <VLAN priority> are 0–7. Default value is 0.
For example:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
You can also specify both the VLAN ID and the VLAN priority with a single command:
racadm setniccfg -v <VLAN id> <VLAN priority>
For example:
racadm setniccfg -v 1 7
75