Huawei R240D Hardware Installation page 106

Remote units
Hide thumbs Also See for R240D:
Table of Contents

Advertisement

R240D
Hardware Installation and Maintenance Guide
Com
pone
nt
PoE
power
supply
AP
Issue 03 (2016-01-26)
Applic
No.
able
Check Item
Scope
dent AC
screws tightly fixed.
Indepen
Four rubber pads are attached to specified positions on the
3
dent AC
bottom of the AC before it is placed on a desk.
The AC is secured in the cabinet or rack by rack-mounting
Indepen
4
brackets or guide rails (or trays), and floating nuts are
dent AC
correctly secured.
The AC card is secured in the cabinet or rack by guide rails
5
AC card
or trays, and the guide rails or trays and floating nuts are
correctly secured.
The AC card is correctly inserted into the device slot and
6
AC card
secured using the ejector lever.
No pins on the backplane are bent when the AC card is
7
AC card
installed.
Indepen
The AC is grounded using a ground cable, meeting surge
8
dent AC
protection requirements.
Indepen
When the AC directly connects to APs, location IDs of the
9
dent AC
APs are provided at the cable connection points.
The proper PoE switch or power adapter is selected, meeting
1
General
AP power supply and onsite environment requirements.
To ensure that the PoE power meets requirements, the PoE
power supply device and APs must be connected through
2
General
CAT5E and CAT6E network cables, and the cable length
cannot exceed 100 m.
Labels must be made for the PoE power cable to identify AP
3
General
locations.
Leave a 20 cm space between PoE power adapters to ensure
4
General
normal heat dissipation.
5
General
The PoE switch is correctly grounded with the ground cable.
Reserve a few downlink network interfaces for the PoE
switch (for example, connect at most 20 APs to a 24-port
6
General
switch) for future capacity expansion.
You are advised to configure dual power modules for a PoE
7
General
switch for power redundancy backup and providing power
for more APs.
The AP installation positions comply with the network
planning report and APs cannot be installed in environments
with strong electrical or magnetic interference or corrosive
1
General
materials. If the onsite environment does not meet
requirements, adjust the AP installation positions properly.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.