Huawei R240D Hardware Installation page 108

Remote units
Hide thumbs Also See for R240D:
Table of Contents

Advertisement

R240D
Hardware Installation and Maintenance Guide
Com
pone
nt
Signal
cable
Issue 03 (2016-01-26)
Applic
No.
able
Check Item
Scope
observation.
Record AP installation positions, MAC addresses, interfaces
13
General
of uplink PoE switches, and IP addresses (APs use fixed IP
addresses) into a table.
The devices required during indoor AP installation, such as
Indoor
14
the splitter, coupler, and antennas are operated in accordance
AP
with specifications.
The APs using a metal shell (with a ground point) must be
15
General
properly grounded.
Outdoor
Unused radio ports should be installed with 50 Ω RF loads.
16
AP
Take lightning protection measures on outdoor APs (the
outdoor APs have built-in 5 kV surge protectors. If
customers require a higher surge protection capability on the
Outdoor
17
feeder ports, they can purchase additional surge protective
AP
devices, which need to be separately grounded). The APs
should be located in the protection scope (within a 45-degree
angle) of a lightning rod.
Outdoor
When an AP is mounted to a pole, the distance between the
18
AP
AP and the top of pole should be at least 30 cm.
Routes of signal cables comply with the engineering design
1
General
document. The signal cables are correctly connected to
facilitate maintenance and capacity expansion.
Radio ports of an AP are correctly connected to radio ports
2
General
A/B/C of antennas.
Signal cable connectors are correctly installed and securely
connected to the device. Wires of each signal cable are
3
General
securely cramped in the connectors and pass connectivity
tests.
Signal cables are orderly routed and not crossed, twisted, or
winded (cables can be crossed at 1 m out of the cabinet). The
4
General
bend radius of cables meets requirements, and the cables are
not excessively bent.
Signal cables are not damaged or broken and have no splices.
Sufficient cable length is reserved. The reserved cables are
5
General
twined and placed properly to facilitate subsequent
maintenance.
Indoor
The optical, power, network, and feeder cables are bundled
6
AP
using straps (one strap every 0.5 m) and securely fastened.
The signal cables shall be bundled at even intervals (about
Outdoor
7
1000 mm), not too tight or too loose. The cables shall be
AP
bundled properly with cable ties placed in neat order. Cut off
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Appendix
102